• Latest Autoclave Provides Sterile Transit Path

Autoclaves

Latest Autoclave Provides Sterile Transit Path

The QCS 150 Pass-Through autoclave is the latest and smallest double-door autoclave to be introduced by Priorclave and is purpose designed to enable laboratories maintain a secure sterile path for media and waste as it passes in and out of a sealed laboratory.

The uncompromising level of safety on this 150 litre front loading autoclave is achieved by way of a design that incorporates the highest level of door interlock settings, preventing doors on either end of the chamber to be simultaneously opened.

The Priorclave QCS 150 Pass-Through autoclave has a 500mm diameter by 740mm deep chamber and has been configured to accommodate up to 20% more load capacity than others steam sterilisers of the same specified size. 

All sterilising processes are controlled by the advanced Tactrol 2 microprocessor which provides simple yet variable settings of process time and temperature, all supported by graphic indication of cycle status. Just set the temperature and time required, select any options needed and press start, operation is fully automatic once the cycle has started.  The tough, clear control panel displays continuously process status.

Priorclave has introduced a choice of two models, a 150L electrically heated Pass-Through autoclave and an externally steam heated design, each offering cooling and automatic timed freesteaming.

Each QCS 150 Pass-Through autoclave is partly bespoke.  Depending on application Priorclave will configure layout of the Tactrol controller to suit lab requirements. 

Where there is concern about bio-hazardous material in the autoclave a microbiological filter can be fitted.  Unfiltered condensate is returned to the autoclave for sterilisation.

The overall design and build of the QCS150 Litres Pass-Through autoclaves take place in its UK manufacturing centre where Priorclave introduces a bulkhead mount at a correct position to facilitate a strong structural fix into a dividing wall between the sterile lab and non-sterile areas.  Once installed the double-door Pass-Through Priorclave is the perfect partner working as an interface between sterile and non-sterile areas


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events