• New Addition to Humidity Control System with Support for Nitrogen Gas Announced
    The Linkam RH95 Humidity Controller with a THMS600 temperature stage and inert gas regulator.

Laboratory products

New Addition to Humidity Control System with Support for Nitrogen Gas Announced

The RH95 Relative Humidity Controller provides precise environmental sample control to Linkam’s range of temperature stages. Since its introduction, there have been many applications found ranging from testing and characterising new photovoltaic materials, research into new battery technologies to the characterisation of pharmaceuticals. The RH95 can be used to control humidity inside one of Linkam’s many temperature stages or other sealed chamber up to a volume of 2000 ml from 5 to 90% RH. Unlike other humidity control systems, no costly dry air supply is required. Ambient air is dried through a specially designed automatic recycling desiccant system and so can be left controlling humidity for months at a time.

Rather than simply monitoring the humidity of the air supplied to the chamber, a sensor is mounted inside the chamber to create a feedback loop to the controller, ensuring precise control. Humidity can have a significant effect on the properties of a material. These include cosmetic surface effects to changes in a sample’s mechanical properties and chemical changes such as creating polymorphs. Such experiments can be performed with the RH95 and Linkam heating cooling stages such as the LTS420 and THMS600 or the TST350 tensile stage.

Linkam have introduced a custom-designed gas regulator for the RH95 controller. As well as drawing air through the chamber, users now have the option to use nitrogen as the carrier gas for the water vapour The regulator allows the use of bottled or piped nitrogen gas with up to 5Bar input, which is automatically regulated down to a safe level for use with the RH95.The use of nitrogen as a carrier gas is important for studies where researchers want to remove the effects of oxidation and corrosion that may be caused by oxygen in ambient air. This opens up a whole new range of applications and experiments for the RH95 such as isolation studies.

For further information please click here.


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events