    Nuclear Pore Complexes (NPCs), large protein structures that span the nuclear membrane in eukaryotic cells and mediate the exchange of materials between the nucleus and cytoplasm, play a vital role in many aspects of cellular physiology including gene expression. Defects in NPC function are implicated in a number of autoimmune diseases, leukaemias and others cancers. Also, nuclear transport plays a pivotal role in viral infections. However, it has been unclear how the NPC facilitates the selective translocation of macromolecules.

    Now, a team from the University of California, Berkeley, has shed light on the step-by-step process of capture, filtering, translocation and release. Signals from single, protein-functionalised quantum dots cargos were captured by an Andor iXon camera in a custom-built near- TIR (total internal reflection) microscope as they tracked through human NPCs. This showed that the overall selectivity of the NPC arises from the cumulative action of multiple, reversible sub steps and a final, irreversible exit step.

    “With their extraordinary photostability and brightness, quantum dots have established themselves as very useful tools for cellular analysis,” said Karsten Weis, Berkeley. “Because of their relatively large size, which is comparable to viral particles, the transport of quantum dots across the NPC is quite slow. This, in combination with their photostability, allowed us real-time tracking over extended periods of time and reconstruction of NPC transport events into high-precision transport trajectories.

    “Tracking of single dots places real demands on detector technology to perform at significantly higher levels of sensitivity and speed. Electron Multiplying CCD (EMCCD) technology, as seen in the Andor iXon camera, amplifies down to single photons and is ideal for these studies,” concludes Weis. According to Mark Browne, Director of Systems at Andor, “The Andor iXon offers the highest sensitivity from a quantitative scientific digital camera, particularly at fast frame rates. Plus, Andor’s proven UltraVac™ vacuum technology ensures both deep cooling and complete protection of the sensor while Andor iCam software enables market-leading exposure switching.”


    Digital Edition

    Lab Asia 32.2 April

    April 2025

    Chromatography Articles - Effects of small deviations in flow rate on GPC/SEC results Mass Spectrometry & Spectroscopy Articles - Waiting for the present to catch up to the future: A bette...

    View all digital editions

    Events

    Medtec Japan 2025

    Apr 09 2025 Tokyo, Japan

    FORUMESURE

    Apr 22 2025 Hammamet, Tunisia

    Korea Lab 2025

    Apr 22 2025 Kintex, South Korea

    Analytica Anacon India & IndiaLabExpo

    Apr 23 2025 Mumbai, India

    Analitika Expo 2024

    Apr 23 2025 Moscow, Russia

    View all events