In order to ensure the validity of your testing you may need to verify that your sieve/s are still compliant with the standard against which they were originally inspected.

A sieve may no longer be compliant to the standard for the following reasons:

  • Deviations from uniformity of mesh such as creases, wrinkles, tears and oversized apertures will render the sieve no longer compliant to the standard.
  • If the mesh is badly scored, or has become loose through use.
  • A sieve frame which has become dented , specifically if the damage prevents the sieve from stacking properly with others of the same size.

How often should I verify continued compliance?

Consideration should be given to the following points:

  • Frequency of use – the greater the use the more frequent verification may be needed.
  • Sieve aperture – finer meshes may need verification sooner than coarser ones.
  • Sieve medium – Condition of the sieving medium (mesh or perforated) is often a good indicator!
  • Test material - Many materials can be quite abrasive and may cause the sieve to become out of specification sooner than you realise.
  • Are you testing for in-house or a third party? – It is more important that your sieves are ‘fit for use’ if you are testing for someone else!
  • Test method
    - standard - is a requirement specified?
    - do you sieve by hand or mechanically?
    - often the test method used may cause the sieve to be out of specification sooner!
  • Are there any industry standard requirements?
  • Are you registered to BS EN ISO 9001:2000 or ISO/ IEC 17025 (which a regular necessitate check on your testing equipment)

Sieve Maintenance
Test sieves should always be used with care, cleaned regularly and stored in a safe place.
Particles should not be forced through the test sieve. Even the gentle brushing of the material through the finer meshes is generally undesirable, but this is occasionally unavoidable for certain materials that are otherwise difficult to sieve. If brushing is found necessary, care should be taken to avoid damage to the sieve and /or particle breakage. Sieves which are in constant use should be inspected regularly for mesh defects.

Test sieves are a precise measuring instrument and should be considered as such.

What can Endecotts do for you?
Our experienced staff are available to offer advice about test sieves, how you can look after them and if they need replacing.

For more information on Endecotts products please click here

sales@endecotts.com
+44 (0) 208 542 8121
WWW.ENDECOTTS.COM


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events