• New Bioinert (U)HPLC Columns for High Accuracy Analysis
    YMC-Accura Triart columns are fully bioinert thanks to their surface coating and are ideally used with a bioinert system.
  • Significantly increased peak heights and areas are obtained using a YMC-Accura Bio C18 column for the challenging analysis of phosphorothioate oligonucleotides.

Columns

New Bioinert (U)HPLC Columns for High Accuracy Analysis

Jul 25 2022

Several substances are able to interact with more common ‘inert’ column hardware materials such as stainless steel or titanium. Critical substances in particular are oligonucleotides or nucleotides. Further sensitive substances are various peptides and proteins as well as coordinating small molecules. The adsorption on metallic surfaces typically leads to peak tailing, loss of recovery and sample carry over. This behaviour can especially be seen when a new column is used without any conditioning before the actual analysis.

For these challenging substances YMC is offering different bioinert hardware options for their YMC-Triart columns. The newly released YMC-Accura Triart (U)HPLC columns are characterised by a bioinert surface coating of the column body and frit. The coating is less hydrophobic compared to the PEEK lining used in the YMC-Triart metal-free (U)HPLC columns. These 2 options allow for the optimum hardware for analyses of any sensitive compound. Further, YMC-Accura columns are ready to use without any preconditioning, which is usually required for analysis of sensitive substances using standard columns.

Due to its organic/inorganic hybrid silica base material, YMC-Triart stationary phases contain no metal impurities. In combination with the bioinert YMC-Accura column hardware, YMC-Triart columns show excellent peak shapes for sensitive compounds, prevent carry over and ensure complete recovery. They are especially ideal for the use in highly sensitive LC/MS analyses.

All 8 YMC-Triart phases are available in inert YMC-Accura columns - with 1.9 µm for UHPLC or 3 or 5 µm for HPLC. The preferred choices for e.g. oligonucleotide or peptide separations are YMC-Triart C18 or YMC-Triart C8 with a pore size of 120 Å. YMC-Triart Bio C18 or Bio C4 with a larger pore of 300 Å are particularly suitable for more hydrophobic oligonucleotides and larger peptides or proteins. Other column options are the polar YMC-Triart Diol-HILIC, the aromatic YMC-Triart Phenyl and PFP and the extremely hydrophobic YMC-Triart C18 ExRS.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events