• Identifying Cannabinoids in Baked Goods with Minimal Sample Preparation

Microscopy & Microtechniques

Identifying Cannabinoids in Baked Goods with Minimal Sample Preparation

Mar 19 2010

Thermo Fisher Scientific, Inc announced a new method for identifying marijuana cannabinoids in baked goods that is faster, easier-to-use and requires less sample preparation. Using ultra high performance liquid chromatography with mass spectrometry detection (UHPLC/MS), the application tests baked goods samples obtained from a local state police forensic laboratory and is detailed in the application note ‘Identification of Cannabinoids in Baked Goods by UHPLC/MS’.

The evidence is first screened for marijuana using simple chemical tests, such as the Duqenois-Levine test and then gas chromatography-mass spectrometry (GC/MS) is used to positively identify cannabinoids. This conventional technique works well for leaf marijuana, hashish and residue collected from smoking paraphernalia. UHPLC/MS however is an alternate method for identifying marijuana cannabinoids in complex food matrices such as baked goods.

Incorporating the Thermo Scientific Accela UHPLC system, the Thermo Scientific MSQ Plus Mass Detector, a single quadrupole mass spectrometer and Thermo Scientific Xcalibur software, the system detected marijuana cannabinoids, Δ9-tetrahydrocannabinol (THC), cannabinol and cannabidiol in the baked goods, a complex food matrix. The team delivered results with simpler sample preparation, no derivatisation and less instrument clean-up time.

The team extracted and separated cannabinoids on a Thermo Scientific Hypersil GOLD PFP column, and it showed that the cannabinoid standards eluted with good resolution at 4.1 minutes (cannabidiol), 5.1 minutes (THC) and 5.4 minutes (cannabinol). The extracts from a brownie and a cookie eluted at 5.1 minutes, testing positive for THC, demonstrating how little sample preparation is required for this method. It is simpler, faster and requires less sample material than traditional GC/MS techniques. Preparation time of ten minutes and a total run time of eight minutes shows the efficiency of UHPLC/MS detection.

The Accela™ is a high-speed chromatographic system that provides fast and efficient chromatographic separations over a range of flow rates and pressures. It features optimised system delay volumes for fast separations and flexible sample format. The innovative quaternary pump is capable of conventional and ultra-high pressures while the Thermo Scientific LightPipe technology provides maximum sensitivity and resolution.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

Asia Labex

Jul 03 2024 Gandhinagar, India

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

View all events