Metrohm's thermometric titration equipment Metrohm, the world's leadingcompany in the field of ion analysis, is proud to announce Titrotherm, its new thermometric titration analysis system.

In its continuing efforts to serve its customers, Metrohm believes that Titrotherm will be a factor in solving titration problems often considered too difficult by other techniques.

Thermometric titrimetry gives the analyst another dimension in analytical problem solving, since it employs the most basic property of chemical reactions - namely enthalpy change - to detect the endpoint.

Thermometric titrimetry offers the analyst speed, accuracy and precision. Thermometric titration is a very versatile determination method and an ideal complement to potentiometric titration. In principle it is suitable for any reaction that produces a sufficiently large temperature change in the sample solution. It is particularly suitable for applications

. for which no suitable potentiometric sensor is available,
. for which no suitable reference electrode is available,
. in which the sample affects the indicator electrode or destroys it,
. for which no solvent is available that is suitable for potentiometry.

The 859 Titrotherm combines innovative sensor technology with Metrohm's titration know-how. The temperature sensor based on semiconductor technology (thermistor), has a short response time of 0.3 s and a high resolution of 10-5 K. This makes the Thermoprobe the ideal sensor for thermometric titration, as it can follow any change in temperature quickly and accurately. Metrohm's Dosino technology has defined a new standard for volumetric titration. The Dosing Unit with its drive motor is mounted on the
reagent bottle and thus guarantees maximum precision with minimum space requirements. The clearly laid out Titrotherm software allows adaptation of the screen view to the particular method parameters and thus provides rapid access to important commands or parameters. The endpoints are determined by
calculating the first and second derivatives of the titration curve; by means of additional optimization parameters, the reproducibility can be improved even further.

Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events