Designed by Erlab®, Captair® Flex® non ducted mobile filtration fume hoods ensures optimal operator protection by being able to adapt itself to the handling of liquid and solid toxic chemicals, separated or combined, in laboratories and clean rooms.

The Captair Flex range can be configured to the protection needs of laboratories. By combining molecular and particulate HEPA H14 filtration technologies, the Flex technology allows the user to do a very large variety of : liquid handlings, such as dilutions, titrations, extractions, transfers ; solid handlings such as sieving, grindings, weighings, formulations, compressions and to combine liquids and solids for dissolutions, filtrations and extractions. This new range can also be adapted to the lab environment such as cleanrooms up to class ISO 5 classification.

Filtration technologies used in the design of captair® Flex® non ducted filtration fume hoods also enable to protect the environment : Since no ductwork is required, the direct discharge of pollutants into the atmosphere is eliminated. It also reduces carbon footprint as it does not generate any pollution linked to energy production unlike a traditional ducted fume hood. The installation is quick and easy. There is no need for a ductwork linked to an air supply / air extraction system, in comparison to traditional ducted systems. The installation can be done at any time, without complex forward planning. Users can also benefit from an immediately available unit, easy to relocate without disturbing room air balance.

This ductwork air balance, essential to the proper operation of a traditional ducted fume hood however is also the source of very important energy consumption. Captair® Flex® filtered enclosures do not generate any energy costs associated with the use of expensive extraction systems or conditioned air supplies. Operational costs can, by consequence, remain at a minimum even when taking into account filters changes.

The compliance of the captair® Flex® range with the 2009 AFNOR NF X 15-211, the major standard related to ductless filtering fume hoods, insures users real performance criteria with regards to : Filtration efficiency (the emission concentration at the filter exhaust must be lower than 1% of the handled product TLV), containment (the maximal concentration of of SF6 tracer gas at the measuring points as described in the standard procedure is 0.1 ppm) and air face velocity (the air face velocity at any point of the front openings must be between 0.4 and 0.6 m/s).

Associated with the Erlab Safety Program (ESP), an exclusive qualification service offered for each unit, laboratories can benefit the 40 years experience of Erlab in offering alternative protection devices for laboratory technicians against chemical hazards.

Lab Asia Dec 2025

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
Tackling sample preparation bottlenecks in environmental analysis
Explore more
Pollution Solutions Online
Call from the Caribbean for Landia mixers to solve rectangular tank mixing challenge
Explore more
Petro Online
Discover a world of industrial solutions
Explore more
Chromatography Today
HPLC Column Performance at Half Price
Explore more