• New High-end Spectrometer with Hybrid Optic for High-precision Metal Analysis

Chromatography

New High-end Spectrometer with Hybrid Optic for High-precision Metal Analysis

Spectro Analytical presents the next generation of SPECTROLAB stationary metal analyzers at the GIFA Foundry Show. This state-of-the-art high-end spectrometer has been equipped with a new hybrid optic, a new readout system and an advanced plasma generator developed by SPECTRO in 2006. The instrument now achieves extremely low detection limits and is especially suited for all metal analysis applications.

"This latest generation of the SPECTROLAB spectrometer is the most flexible and most accurate OES instrument using spark excitation available. It is suitable for all common matrices that can be combined as needed. In addition, detection limits of a few mg/kg have been obtained," reports Kay Toedter, Product Manager for Stationary Metal Analyzers at SPECTRO. "

The most important technological advance achieved in this version of the SPECTROLAB is its hybrid optic that directly processes the light from the spark stand with up to 108 PMT detectors and 22 CCD sensors. Parallel utilization of the two detector technologies achieves detection limits with a previously impossible flexibility. The SPECTROLAB, for example, achieves detection limits below 1 mg/kg for typical applications like the determination of trace elements (e.g., Al, B, Ca, Cu und Mg) in iron alloys.

In the CCD segment, the instrument operates with a focal length of 750 mm, enabling much higher resolution measurements. The repeatability of results is extraordinarily high in the argon atmosphere thanks to the instrument's pressure control and temperature stabilization. This advanced arrangement ensures a maximum in measurement reproducibility.

In order to fully take advantage of the potential in the hybrid optic, the SPECTROLAB was outfitted with a new readout system. In the PMT segment, instead of integrating the total light over a fixed measurement time, the light output for each individual spark is measured with integration times in the microsecond range. "This leads to more reliable results with greater statistical certainty," clarifies Kay Toedter.

Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events