Optical coherence tomography (OCT) is an advanced high-resolution non-invasive imaging tool, which delivers three-dimensional (3D) images from the microstructure compartments within the skin tissue. Using OCT one can extract optical properties (scattering coefficient and anisotropy factor) of normal or diseased skin to generate an optical model for skin, which can be used for diagnosis. To verify and
validate the optical properties extraction algorithm a tissue-like optical phantom is needed. If the phantom can be multilayer, it can model the skin more accurately.

WHAT IS PHANTOM AND WHY IS IT NEEDED?
Phantom is a virtual tissue with well-controlled optical properties (refractive index, scattering coefficient, anisotropy factor and absorption coefficient) and can be constructed in solid or liquid states depending on its application. Phantoms are being used for testing the design of the system, system optimisation, and performance evaluation of the system. In optical imaging modalities in particular, phantoms are used for measurement/evaluation of the system parameters such as longitudinal and transversal resolutions, image contrast, point spread function (PSF), system sensitivity, system differentiability between two types of tissues, and system detectability of a certain concentration. In this study, we used phantoms to evaluate the accuracy and precision of the optical properties extraction algorithm in calculating the values of scattering coefficient and anisotropy factor.

HOW CAN WE EXTRACT OPTICAL PROPERTIES FROM OCT IMAGES?
The optical properties (scattering coefficient and anisotropy factor) can be extracted from the OCT images by fitting the OCT signal which is obtained based on extended Huygens-Fresnel (EHF) principle, onto the averaged A-line vector in a specific region. The fitting procedure and corresponding curves are shown in Figure 1 and Figure 2, respectively. One can generate an optical model for skin by specifying the range of variation of the optical properties for the healthy skin. Then the values out of this range can be used for the diagnosis of diseased skins.

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events