• Optimised MS, Getting a result within seconds

Mass Spectrometry & Spectroscopy

Optimised MS, Getting a result within seconds

Sep 07 2021

Real-time, On-line Mass Spectrometer

ACE 1100 Ion-Molecule Reaction Mass Spectrometer (IMR-MS) is an optimised Real-time mass spectrometer for qualitative and quantitative analysis of Volatile Organic Compounds (VOCs) created by YOUNG IN ACE. GC-MS and LC-MS use chromatography systems (GC, HPLC) for the separation of analysis compounds and need the interface between mass spectrometer and chromatography system. In contrast with GC-MS & LC-MS, IMR-MS loads sample directly into the mass spectrometer and can get analysis results immediately in real-time. It can be used not only in the laboratory but also in the place where on-site analysis is required, and on-line monitoring is necessary.

Principle of ACE 1100 IMR-MS

ACE 1100 IMR-MS uses a Soft Chemical Ionization method (Soft CI) and it ionizes the sample molecule itself or minimises the fragmentation of the target molecule. This ionization method assists achieve a simple and accurate mass spectrum.

Reagent ions (H3O,NO+, O2+) are produced from water and air passing through the microwave plasma for chemical ionization of analysing the sample molecules. They move through the First mass filter to the Reaction chamber, react with injected sample molecules to ionize the components. Ionized molecules are measured on the detector via the Second mass filter according to their mass-to-charge ratio.

Even non-experts can get the result with simple software and change the setting of the equipment or adjusting the method easily.

  • Ion source
  1. Normal water and air pass through microwave plasma to produce Reagent ions (H3O,NO+, O2+)
  • First mass filter
  1. Selects Reagent ion, transfer to the Reaction chamber
  2. On Scan mode, transfer Reagent ion by orderly
  • Reaction chamber
  1. Reagent ion and Analyte react to ionize analyte molecules
  • Second mass filter
  1. Separates the ions which are produced during passing the Reaction chamber according to their mass-to-charge ratio
  • Electron multiplier
  1. Detects by amplifying signals from passed ions

Features

  • FAST analysis
  1. Direct analysis, save time without sample preparation and separation procedures
  • REAL-TIME analysis
  1. Immediately getting a result with real-time analysis within tens of seconds
  • ACCURATE results
  1. Clear interpretation of results with simple mass spectrum
  2. Ionize the parent molecule itself using chemical ionization
  • ON-LINE monitoring
  1. Continues result acquisition(24hrs/7days)
  • MOBILE LAB
  1. Mounted in vehicle for Mobile Lab
  2. Immediate analysis on-site
  • EASE OF USE
  1. Easy data processing with software
  2. Expert and beginner can operate easily

Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events