• Report on Reaction Monitoring Research using a Benchtop NMR System at the University of Glasgow

Mass Spectrometry & Spectroscopy

Report on Reaction Monitoring Research using a Benchtop NMR System at the University of Glasgow

Feb 23 2015

Professor Lee Cronin holds the Regius Chair of Chemistry at the University of Glasgow. Research in the Cronin Group is motivated by the fascination for complex chemical systems and the desire to construct complex functional molecular architectures that are not based on biologically derived building blocks. They are developing a new approach to the chemical sciences which they call Chemical Cybernetics. This combines robotics, algorithms, flow chemistry and reaction programming. Over a number of years, Professor Cronin and his colleagues have used use a lot of integrated techniques to explore chemical reaction systems.

The recent advent of benchtop NMR and having been inspired by previous self-optimised flow systems with in-line analytical monitoring, the Cronin Group has extended this concept so that multinuclear and 2D NMR can be performed in the fume hood. The Magritek Spinsolve benchtop NMR provides analyses from the single sample in a standard 5 mm sample tube to performing in-line 1H, 13C 19F and 2D NMR analysis. They have also combined in-line 1H NMR with computational techniques to make a self-optimising reactor. They have taken their benchtop NMR system an d created a flow system using nothing more than simple plastic tubing and non-dueterated solvents.

Before benchtop NMR, Professor Cronin employed both benchtop and high resolution mass spectrometry along with flow IR and UV systems. As he said: "We now use the Magritek Spinsolve in the 'flow' mode that we developed in my lab. For our work, this is important as it allows us to look at reaction dynamics. We can run entire reactions (no need for deuterated solvent) or look at things in real time; we can adjust reaction outcomes as a function of NMR. This makes for a very flexible system."

Previous systems integrating in-line NMR spectroscopy had been limited to bypass configurations, flow cells in high-field magnets or applied microfluidics. The Cronin approach takes advantage of a compact permanent low-field magnet (43 MHz) based on the Hallbach design. As reported in a recent paper in the Royal Society of Chemistry journal, Chemical Science, "Despite the low field of the magnet, Spinsolve has remarkable sensitivity and stability." 


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

View all events