MALS Detectors Enable Easy and Reliable Transmembrane Protein Characterisation

Wyatt Technology Corporation announced that the Université de Provence and Université de la Méditerranée in Marseille, France, have implemented the innovative Wyatt Multi-Angle Light Scattering (MALS) detectors for use in their Biological Macromolecules Joint Research Unit. The instruments are used for the characterisation of transmembrane proteins, determining their quaternary structure and following their retention during protein handling. Transmembrane protein characterisation is of increasing importance for the pharmaceutical industry as these proteins are key determinants of the pharmacokinetics of drugs. Wyatt’s MALS detectors offer an easy-to-use, efficient alternative to traditional laborious in vitro characterisation techniques.

When present in their native environment, transmembrane proteins are inserted via hydrophobic segments in a lipidic bilayer. Conventional in vitro characterisation of
transmembrane proteins requires the extraction of the proteins from the membrane and subsequent maintenance in a soluble and native state. This is generally achieved using amphiphilic compounds, termed detergents, yielding proteindetergent complexes (pdc). However, several transmembrane proteins are naturally found as oligomers and maintaining this precise macromolecular assembly is a crucial issue for further studies. In addition, classical SEC column calibration does not
apply in the case of pdc, whose volume and shape depends on the detergent fraction.

For this particular application, Wyatt’s MALS instruments were used to perform a quaternary structure study of the Methanosarcina mazei CorA transporter in two detergents. MALS technology was used in conjunction with refractometry and UV280nm absorbance. This combined solution was able to solve a ‘two equations with two unknown parameters’ system, providing masses of protein and detergent in each pdc. This approach provided hints about the retention of the native, and thus active, membrane protein quaternary structure, which is a crucial issue for crystallization or other biochemical studies, without performing laborious activity tests.

Experimental results prove that Wyatt’s MALS instrumentation surpasses traditional in vitro characterisation techniques, providing a straightforward method capable of accurate, reliable characterisation of transmembrane proteins.


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events