• Add more confidence to your UHPLC-MS analysis

Laboratory products

Add more confidence to your UHPLC-MS analysis

For your highly sensitive UHPLC-MS analyses, how can you reduce noise and additional signals to a minimum? Our new high-end UHPLC-MS solvents raise the standard for low baseline noise and clean mass spectra.

Our new range of advanced UHPLC-MS LiChrosolv® solvents have been developed to exceed all expectations, providing rapid and reliable results in both ESI/APCI positive and negative ionisation modes.

Thanks to their lowest level of background noise and ion suppression, this quality ensures the optimum ionisation efficiency to enable the highest sensitivity. With these features, use of these solvents can also help to extend column lifetime.

To ensure that you have confidence in your results, we specify the lowest possible limit of polyethylene glycol (PEG) impurities in all our UHPLC-MS solvents.

Our advanced UHPLC-MS LiChrosolv® solvents have been designed to meet the highest requirements of UHPLC-MS in research and quality control, including proteomics and metabolomics as well as environmental, clinical, food or industrial testing applications.

A new standard for the unlimited application of ultra- high-performance chromatography has been set.

Features & Benefits

  • Suitability tested and specified for UHPLC-MS and UHPLC-UV: for analytical flexibility
  • Specified quality in positive and negative ESI and APCI MS for lowest detection limits and confidence in analyses in all important MS modes (test 1)
  1. - ESI/APCI (+) < 2 ppb
  2. - ESI/APCI (-) < 10 ppb
  • Lowest impurity profile: for interference-free baselines (test 2)
  • Microfiltration through 0.2 µm filter (test 3)
  1. - prolonged lifetime of filters and mechanical parts in HPLC systems
  2. - reduced risk of column clogging
  • Packaged in borosilicate glass bottles: minimized contamination with metal ions
  • Lowest levels of trace metal impurities: for minimized metal ion adduct formation
  1. - <5ppb

Lowest level of polyethylene glycol (PEG) impurities in our entire UHPLC-MS solvent lineup to give you confidence in your results (PEG S/N signal-to-noise- ratio < 50)

For further information please click here.


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events