• A Safety Cabinet That Combines Performance, Quality, Reliability and Dependability.

    Glove boxes

    A Safety Cabinet That Combines Performance, Quality, Reliability and Dependability.

    The LabGard 425 Class II, from NuAire, Type A2 Biological Safety Cabinet combines performance with quality construction for reliability and value where safety and dependability are not an option. The LabGard 425 is offered in a variety of standard sizes ranging from 2' to 6' widths, along with superior personnel, product and environment protection, it is plain to see why this cabinet is the best selling Bio-Safety Cabinet in the world.

    The HEPEX? Zero Leak Airflow System integrated in the cabinet has true Laminar Airflow with uniform down-flow velocity of 60 FPM over the sterile work-zone, minimizing cross contamination, keeping the cabinet quiet and reducing vibration. The HEPEX? system eliminates direct blower blasts to the HEPA filter, preventing cabinet or gasket leaks and filter failure. This system also allows change of the HEPA filter without exposing the dirty, contaminated side of the filter to the laboratory or service technician.

    The newly designed modular Control Center offers three panels to choose from, still maintaining the eye-level on / off switches for the exterior mounted fluorescent lights, interior convenience outlet, blower motor, sliding window alarm, reset switches for power and outlet circuit breakers, air flow control and a minihelic gauge to display pressure drop.

    The LabGard 425 utilizes an ergonomic design for user comfort and adjustability to meet the requirements of the Americans with Disabilities Act (ADA). The variety of options and accessories allow the cabinet to be tailored to each user's individual needs. NuAire serves laboratory professionals with better construction, less maintenance, lower operating costs, and a safer, longer lasting superior safety cabinet.


    Digital Edition

    ILM 50.2 March 2025

    March 2025

    Chromatography Articles - Effects of small deviations in flow rate on GPC/SEC results Mass Spectrometry & Spectroscopy Articles - Waiting for the present to catch up to the future: A bette...

    View all digital editions

    Events

    Analytica Vietnam

    Apr 02 2025 Saigon, Vietnam

    Medtec Japan 2025

    Apr 09 2025 Tokyo, Japan

    FORUMESURE

    Apr 22 2025 Hammamet, Tunisia

    Korea Lab 2025

    Apr 22 2025 Kintex, South Korea

    Analytica Anacon India & IndiaLabExpo

    Apr 23 2025 Mumbai, India

    View all events