• GPC with Parallel Processing for Increased Sample Clean-Up Throughput

Chromatography

GPC with Parallel Processing for Increased Sample Clean-Up Throughput

Jun 24 2009

Pickering Laboratories, Inc has announced an innovative GPC Quattro gel permeation chromatography (GPC) instrument from LCTech GmbH and will be the exclusive North American distributor of this
latest GPC instrument when it is released in the second quarter of 2009.

The GPC Quattro can be used to run four GPC columns with the same method or four fully independent methods, providing a fourfold increase in productivity in comparison to traditional single-column
instruments. For example, more than 40 samples can be processed during a 9-hour working day while running the DFG S19 method on a standard GPC column. Yet the GPC Quattro 4-column GPC is cost
competitive with single-column GPC instruments and costs much less than existing multi-column instruments.

The GPC Quattro is designed for the clean up of complex animal tissues, food products and environmental samples by separating high molecular weight matrixes from analytical samples. The system provides an
excellent tool for analysing polyaromatic hydrocarbons (PAH), hydrocarbon pesticides, polychlorinated biphenyls (PCBs), antibiotics, mycotoxins such as aflatoxins and ochratoxins, and other semivolatile
compounds. The concentrated samples can be easily analysed by GC, GC-MS, HPLC and LC-MS. A typical application for the instrument is sample cleanup of fish prior to GC-MS detection of PCBs and pesticides.

The GPC Quattro is designed for mid-sized laboratories interested in achieving very high throughput at an economical price. The GPC Quattro system includes full error management and the storage run timers
make it easy for users to resume the sample or abort the run in the case of a power outage. Safety features include high and low pressure shut-off and waste level sensor. A safety timer calculates the minimum
time from flow rate and sample loop size for re-switching to load position.

The GPC Quattro instrument has a maximum operating pressure of 1000 psi (70 bar). The higher pressure capabilities of the GPC Quattro allow it to run stainless steel preparative GPC columns that have shorter
run times and to reduce solvent consumption. The flow rate can be varied from 1 to 40 milliliter per minute. The operator manually injects the samples and the system will automatically process the GPC runs.
During the run, the display will provide complete information including an overview screen that shows the progress of all four runs and screens with more detailed information on the individual columns.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

Asia Labex

Jul 03 2024 Gandhinagar, India

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

View all events