• New Automated Sample Preparation System for Dioxin and PCB Analysis Processes 3,500 Samples per Year

Chromatography

New Automated Sample Preparation System for Dioxin and PCB Analysis Processes 3,500 Samples per Year

Aug 15 2016

LCTech GmbH presents its new automated sample preparation system DEXTech™ Plus.

Tedious and elaborate sample preparation makes the sample processing time and cost-intensive. When developing its new system for automated sample preparation in dioxin and PCB analysis LCTech focused on shortening the process time, increasing the flexibility of the system, allowing easy handling, and achieving lower costs per sample.

With the system DEXTech™ Plus, LCTech as the specialist for automated sample preparation succeeded in reducing the processing time to only 35 minutes depending on the sample including conditioning and fractionation. This allows to process up to 3,500 samples per year with only one system. 4 systems in parallel achieve a sample throughput of up to 14,000 samples per year, making the system a perfect solution also for high throughput laboratories.

The 3 column system can be equipped with different ready-to-use columns depending on the analysed matrix or the requested fractions. Insertion of the columns is very simple: The columns are clicked into the system in seconds, without any tools and without screwing. Afterwards they are electrically locked (patented system).

The method set-up is done via touch-screen, where the parameters can be configured freely or pre-stored default methods can be selected.

After the sample vial has been placed into the system, the sample will be quantitatively loaded into the sample loop by the syringe pump. During the whole process the sample doesn’t come in contact with the syringe pump at any time. Due to that, as well as for the systemic rinsing of the device and the exchange of the columns, cross-contamination is reliably avoided.

Various safety features like leakage sensor, overpressure control, and waste level sensor ensure the safety of the users. The locking of the columns is only possible, if the door is closed and the system operates entirely in the low voltage range. An extractor hood is not required.

DEXTech™ Plus provides an integrated USB-port for reporting and documentation and is compliant with the EPA method and European regulations.


Digital Edition

International Labmate Buyers' Guide 2024/25

June 2024

Buyers' Guide featuring: Product Listings & Manufacturers Directory Chromatography Articles - Enhancing HPLC Field Service with fast-response, non-invasive flowmeters - Digital transformatio...

View all digital editions

Events

Asia Labex

Jul 03 2024 Gandhinagar, India

EuCheMS Chemistry Congress

Jul 07 2024 Dublin, Ireland

HPLC 2024

Jul 20 2024 Denver, CO, USA

ICMGP 2024

Jul 21 2024 Cape Town, South Africa

ADLM 2024

Jul 28 2024 San Diego, CA USA

View all events