• Avoiding unexpected nitrosamine contamination in pharmaceuticals

Chromatography

Avoiding unexpected nitrosamine contamination in pharmaceuticals

In recent years, nitrosamine contamination has emerged as one of the most pressing challenges for pharmaceutical manufacturers. Following the detection of NDMA in valsartan in 2018, similar issues surfaced in ranitidine, metformin, and other products—leading to large-scale recalls, regulatory scrutiny, and financial penalties.

As regulators like the EMA and FDA now require comprehensive nitrosamine risk assessments, manufacturers face a difficult task: many nitrosamines can form from unexpected sources such as excipients, raw materials, packaging, or even during synthesis. Traditional targeted testing may miss these hidden threats.

Why conventional testing isn't enough

Most laboratories rely on targeted methods to detect known nitrosamines. But if a nitrosamine isn't on the list—or if it's formed through new pathways during production—it can easily go unnoticed. This leaves manufacturers vulnerable to undetected contamination and subsequent non-compliance.

A smarter approach: Apparent total nitrosamine content (ATNC)

Ellutia’s Automated Total Nitrosamine Analyser (ATNA) offers a powerful screening solution through ATNC analysis. Unlike targeted methods, ATNC testing detects all nitrosamines by identifying the shared nitrosamine functional group, without needing reference standards for each compound.

  • Rapid screening to ppb levels
  • Non-targeted detection catches unknown nitrosamines
  • Optimised chemistry eliminates false positives from nitrites
  • Unattended operation for up to 20 hours with high throughput

This makes the ATNA ideal for high-volume quality control labs that want to identify issues early, conserve analytical resources, and meet evolving regulatory requirements with confidence.

What happens if ATNC is high?

If the ATNA flags a high ATNC value, a follow-up analysis with GC-TEA or other methods can be used to identify the specific nitrosamines present. Ellutia’s GC-TEA system, with its ability to detect all volatile nitrosamines (including unknowns), provides the highest confidence in final confirmation.

See the ATNA in action

Discover how Ellutia’s ATNA system works and how it can help your lab stay ahead of nitrosamine risks. Watch our free on-demand webinar now.


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events