• The New contrAA® 600 - High Resolution Continuum Source AAS for the Graphite Furnace Technique
    Fig. 1 : contrAA® 600 with autosampler for liquid samples
  • Fig. 2 : contrAA® 600 with autosampler for solid samples

Chromatography

The New contrAA® 600 - High Resolution Continuum Source AAS for the Graphite Furnace Technique

With the High Resolution Continuum Source Atomic Absorption Spectrometer (HR-CS AAS) contrAA® 600, Analytik Jena AG is now offering a pure graphite furnace system (GF) with all of the benefits of the HR-CS AAS:
- Just one light source for all elements
- Unique simultaneous background correction
- New information content
- Fast! Simple! Efficient!

With the new contrAA® 600,the contrAA® family is now complete. The family already includes the contrAA® 300 for flame and hydride technique and the contrAA® 700, a compact, all-round system for flame, hydride and graphite furnace technique.

With a xenon lamp as a continuous radiation source, the entire wavelength range relevant for AAS is immediately available in the HR-CS AAS. Molecule bands can now be assessed as well. This allows additional elements, such as sulphur, phosphorus or fluorine to be analysed in the blink of an eye.

Functionality comes first with the contrAA® 600. Fully automated processes and intelligent accessories optimise the analysis process. The transversely heated graphite tube furnace and the temperature control ensure optimal atomisation conditions, precise results and a long service life of the graphite tubes.

Take advantage of the benefits of the HR-CS GF AAS in combination with the direct solid analysis technique or the HydrEA technique of Analytik Jena AG.

Solid analysis technique –solid AA®
Solid samples are analysed directly, without elaborate preparations of the samples with the help of the solid analysis technique:
- Analysis of the original sample
- Best choice for routine application
- Immediate results
- Extremely high sensitivity

HydrEA
The combination of hydride and graphite tube techniques opens up completely new perspectives in the detection of hydride forming elements, such as arsenic or selenium:
- Best detection limits
- Matrix-free analysis
- Minimisation of contamination problems
 


Digital Edition

Lab Asia Dec 2025

December 2025

Chromatography Articles- Cutting-edge sample preparation tools help laboratories to stay ahead of the curveMass Spectrometry & Spectroscopy Articles- Unlocking the complexity of metabolomics: Pushi...

View all digital editions

Events

Smart Factory Expo 2026

Jan 21 2026 Tokyo, Japan

Nano Tech 2026

Jan 28 2026 Tokyo, Japan

Medical Fair India 2026

Jan 29 2026 New Delhi, India

SLAS 2026

Feb 07 2026 Boston, MA, USA

Asia Pharma Expo/Asia Lab Expo

Feb 12 2026 Dhaka, Bangladesh

View all events