New System Provides High Efficiency Multi-Sample Prep Processing
Feb 07 2020
The Nexera Prep Series consists of multiple related products with the LC units as the core. Users select a pump, autosampler and detector to build a system according to the purpose of the preparative work. Systems can be configured using related products such as the LH-40 Liquid Handler, FRC-40 Fraction Collector, Shim-pack Scepter LC Column for Analysis and Preparative Work, and Column Hub.
Preparative purification is generally performed following a multi-step workflow, which requires experience and time:
- Selection of system configuration and preparative column size based on the amount of purified sample or injection volume required
- Selection of fraction collector and container size according to the intended purpose
- Investigation of separation conditions in analytical scale
- Optimisation of preparative LC conditions
- Confirmation of the purity of collected fractions
In addition to these steps, in some cases salts need to be removed or solvent needs to be evaporated after purification, requiring additional time and effort.
The Nexera Prep Series reduces the time spent on examining conditions using the software’s fractionation simulation function. It also enables simplified, fast operation in transition from analytical to preparative scale, with a column portfolio that covers a wide range of sizes. Furthermore, Shimadzu’s unique UFPLC (Ultra Fast Preparative and Purification LC) high-purity purification system reduces the time required for powderisation via the elution of desalted target components with an organic solvent. This product satisfies a number of user demands, such as efficient desalting and powderisation, multi-sample and multi-fraction analysis, effective separation at low cost and the ability to check the purity.
Specifically, the product can be used for the following purposes:
- Concentration and purification of immunosuppressive agents
- Preparative work for impurities in degradants of medicinal agents
- Separation and purification of functional components from natural materials
- Consecutive analysis to separate and purify polymers and their additives and confirm the purity
With the fractionation simulation function of the LabSolutions analysis software and the Shim-pack Scepter LC column for analytical and preparative HPLC, which offers excellent scalability, the product reduces the time required for investigating preparative work conditions. The LH-40 Liquid Handler can be used both, as a fraction collector and as an autosampler for large-volume injection with liquid surface detection function (option). It also enables seamless purity checks through re-injection (option) of collected sample after fractionation. Additional features including a sample rescue protocol to collect the sample from the system if an error occurs after an injection, a function to automatically extract the target peaks only, and high-purity preparative purification using detector signals from up to four channels, enable more efficient operation.
Samples must be in a state of concentrated solution or dry powder to analyse their structure or to store them. When a solution contains water, it takes time to dry and concentrate it. When a salt such as trifluoroacetate has been added, it remains in the crystal of the compound, lowering the purity and negatively influencing pharmacokinetic studies and other tests. Shimadzu’s unique, automated UFPLC purification system introduces fractions containing the target compound, separated in a preparative column, into a trap column. Salt and water are then washed off and elution is induced with an organic solvent. This reduces the time required for drying, providing compounds with a high level of purity.
Both the LH-40 Liquid Handler and FRC-40 Fraction Collector are designed to save installation space, requiring only half the space of other vendors’ products. They support containers of a form and size suitable for the recovered quantity. Up to six units can be connected, so up to 3240 10 mm diameter test tubes can be placed. Using the new Column Hub, up to six columns and four flow-line switching valves can be installed, enabling the compact configuration of various systems.
More information online