• New Chromatography Consumables exhibited at Pittcon 2013 

Chromatography

New Chromatography Consumables exhibited at Pittcon 2013 

Apr 30 2013

Thermo Fisher Scientific Inc have announced that it featured a number of new chromatography consumables within booth 1835 during Pittcon 2013. Among them are several columns designed for improved analysis of chemical compounds.

The Company has added five phases to its family of Thermo Scientific Accucore solid core HPLC columns: Accucore Polar Premium, a rugged amide-embedded C18 phase offering complementary selectivity to conventional C18 columns; Accucore Phenyl-X, featuring a proprietary reversed-phase shape selectivity with high aromatic selectivity; Accucore C30, designed for high shape selectivity for hydrophobic, long chain, structurally related isomers; Accucore Urea-HILIC for HILIC, designed for selectivity and low ion exchange activity; Accucore 150-Amide-HILIC, designed to separate hydrophilic biomolecules in HILIC mode, intended for glycan separations.

Also new to the portfolio are Thermo Scientific Acclaim SEC-300 and SEC-1000 size exclusion HPLC columns designed for high-resolution separation of water soluble polymers and oligomers. They are optimised for determining molecular weight distribution and characterisation of water soluble polymers used in a wide range of products found in pharmaceuticals, cosmetics, food and industrial processes. The columns are intended for research use only.

For high-resolution and high-throughput trace LC-MS analysis of the herbicides diquat and paraquat in plants, Thermo Fisher Scientific features the Acclaim Trinity Q1 HPLC column. Tests have demonstrated that the new column delivers the retention, resolution, peak shape and speed needed to improve diquat and paraquat analysis in common terrestrial and aquatic plant matrixes, without the need for pairing reagents or exotic mobile phases.

Also launching at Pittcon is the Thermo Scientific National SureStop vial, designed to eliminate variations in sealing inherent in manual tightening, while optimising septum compression each time. The threads contain a ‘stop’ designed to prevent under- and over-tightening. Evaporation studies have shown that the SureStop vial produces the lowest loss to evaporation and the lowest standard deviation in evaporation of any mainstream 2mL vial. This can protect data quality by reducing a source of experimental variation.


Digital Edition

LMUK 49.7 Nov 2024

November 2024

News - Research & Events News   - News & Views Articles - They’re burning the labs... Spotlight Features - Incubators, Freezers & Cooling Equipment - Pumps, Valves & Liquid Hand...

View all digital editions

Events

MEDICA 2024

Nov 11 2024 Dusseldorf, Germany

FILTECH

Nov 12 2024 Cologne, Germany

Intech

Nov 12 2024 Tel Aviv, Israel

analytica China

Nov 18 2024 Shanghai, China

Pharma Asia

Nov 20 2024 Karachi, Pakistan

View all events