Premier Control Technologies Logo
Premier Control Technologies Flow, pressure, level and temperature solutions

Alicat MB - Portable Gas Mass Flow Meter

Delivery icon

5 - 7 day fast-ship available

  • 98+ Preloaded Gases and Gas Mixtures
  • 10,000:1 turndown ratio
  • 5-ms speed of response
  • No warm-up time, ready to go in 1 second
  • ±0.6% of reading accuracy on most devices

Laboratory grade flow verification, anywhere you need it

Alicat MB Series portable mass flow meters monitor your mass and volumetric flow as well as your process pressure and temperature. This is all done simultaneously and every MB series comes preloaded with 98 gases and gas mixtures, you can even add your own gas blends! Now equipped with up to 18 hours battery life and a 3.5 hour recharge time via USB charger.

The portable mass flow meter is repeatable and accurate with calibrations up to ±0.5% of reading accuracy.

Every device has a 10,000:1 turndown ratio with full scale flow rates starting from 0.5 SCCM and going up to 5000 SLPM.

Alicat MB Series comes with a backlit LCD as standard, along with RS-232 communications over a USB type B connection.

Every Alicat device is backed by the manufactures limited life time warranty and ships with a NIST traceable calibration certificate.

MB series portable mass flow meters have a maximum operating pressure of 175 PSIG.

Key specifications

The data in the table below are standard configurations for models 10 SCCM full scale through 20 SLPM full scale. Please refer to the Mid-flow data sheet for full details.

Mass Flow Accuracy at Calibration Conditions1±0.6% of reading or ±0.1% of full scale, whichever is greater
High Accuracy Option1±0.5% of reading or ±0.1% of full scale, whichever is greater
Bidirectional Option1No additional uncertainties
Repeatability (2σ)±(0.1% of reading + 0.02% of full scale)
Flow Measurement Range0.01–100% of full scale
Temperature SensitivityMass flow zero shift: ±0.01% of full scale per °C from tare temperature
Mass flow span shift: ±0.01% of reading per °C from 25°C
Pressure SensitivityMass flow zero shift: ±0.01% of full scale per atm from tare pressure
Mass flow span shift: ±0.1% of reading per atmosphere from calibration conditions
Operating Temperature Range−10–60°C
Temperature Accuracy±0.75°C
Operating Pressure Full Scale160 PSIA

1 - Stated accuracy is after tare under equilibrium conditions, includes repeatability and linearity.

Video: The Fastest Way to Validate your Mass Flow Rates

Measure your flow rates out on the field with this rechargable flow meter.

Applications

Common process applications and industrial uses include:

  • Flow Verification of a Gas Chromatograph
  • Calibration, Verification & Validation
  • Environmental

Other features

Model numbers

  • MB-0.5SCCM-D
  • MB-1SCCM-D
  • MB-2SCCM-D
  • MB-5SCCM-D
  • MB-10SCCM-D
  • MB-20SCCM-D
  • MB-50SCCM-D
  • MB-100SCCM-D
  • MB-200SCCM-D
  • MB-500SCCM-D
  • MB-1SLPM-D
  • MB-2SLPM-D
  • MB-5SLPM-D
  • MB-10SLPM-D
  • MB-20SLPM-D
  • MB-50SLPM-D
  • MB-100SLPM-D
  • MB-250SLPM-D
  • MB-500SLPM-D
  • MB-1000SLPM-D
  • MB-1500SLPM-D
  • MB-2000SLPM-D
  • MB-3000SLPM-D
  • MB-5000SLPM-D

Industries

The Alicat MB - Portable Gas Mass Flow Meter is widely used in the following industries:

Alicat recalibration service

Alicat Calibration and Service Centre

We provide a certified annual recalibration service on all Alicat mass flow meters and mass flow controllers. Further details on our recalibration service.

Related products

Manufacturer

Alicat Scientific
TOP