Microscopy & Microtechniques

Electron Microscopy Reveals Secrets of Nanocrystal-Assembly in Coral Skeletons

Apr 14 2014

Author: Renée van de Locht on behalf of University of York

Free to read

This article has been unlocked and is ready to read.

Download

One of the most important examples of mineral forming organisms are corals, in particular reef-building corals, which play central roles in the marine ecology by hosting 25% of marine livestock as well as the economy via coastal protection, tourism and fishery. The mechanical stability of coral colonies is caused by a massive accretion of a calcium carbonate based exoskeleton. We are interested in the relation between growth conditions, such as the chemical composition of seawater, the pH value and the temperature on the microstructure of the mineral deposited by the corals. For this purpose we focused on the details of the microstructure down to the atomic level to understand the patterns of assembly of the nanocrystalline building blocks constituting the skeleton. These studies were undertaken using state-of-the-art electron microscopy available at the University of York and form parts of a collaboration with world-leading research groups in the area of Marine Science at the University of Western Australia and the University of St Andrews.

Transmission Electron Microscopy (TEM)
Instrumentation
TEM samples were predominantly analysed at the York Jeol Nanocentre utilising a JEM 2011 (LaB6 heated filament with an EDX detector for elemental analysis) and JEM 2200 FS (field emission, double Cs aberration corrected with EDX detector for elemental analysis and an in-column omega filter for EELS and EFTEM) TEM operated at 200kV.  
Additionally TEM analysis was performed at the Centre for Microscopy, Characterisation and Analysis (CMCA) at the University of Western Australia using a JEM 2100 TEM (LaB6 heated filament with an 11M pixel Gatan Orius digital camera and a Gatan Tridiem energy filter for EELS) operated at 120 and 200 kV and a JEM 3000 F FEGTEM (field emission with a 1M pixel Gatan 694 MSC digital camera and a Gatan GIF2000 energy filter for EELS and EFTEM) operated at 300 kV.
Microscope conditions and beam damage; Electron microscopy
During electron microscopy image or data acquisition, beam damage and sample contamination should be considered. Damage caused by elastic interactions can affect the original structure and/or chemistry of the specimen by a variety of phenomena such as the breaking of chemical bonds, the displacement of atoms, creating point defects or simply the heating caused by phonons interacting with the sample [1]. Contamination is caused by the deposition of carbonaceous material due to hydrocarbons that are present in the TEM chamber reacting with electrons from the beam forming hydrocarbon ions and condensing on the irradiated specimen surface [2]. In case of biogenic samples a hydrocarbon organic film is often naturally present on the specimen itself, which greatly enhances this phenomenon. Especially during analytical EM: EDX and EELS, beam damage is problematic as the beam is often condensed on a spot for several tens of seconds’ acquisition time. This can cause severe structural damage: removal of material, and re-deposited together with the previously mentioned hydrocarbons on the specimen surface. Beam damage also occurs during high resolution imaging as the high magnification (>400 000 x) acts as a condensed beam on a small surface area, this often results in damage to the crystal lattice fringes (Figure 1).
To reduce beam damage imaging and diffraction is performed using predominantly a LaB6 filament TEM instead of a field emission gun, which has a higher intensity. Furthermore small condenser apertures (40 and 20 μm for condenser aperture n. 3 and 4 respectively JEM 2200 FS, and 20 and 10 μm for the JEM 2011) and small spot size (~2 nm) are used at all times. The disadvantage of these measures is reduced intensity and contrast in the image. Else, the TEM is operated at a standard 200 kV.
Sample preparation
Coral specimens
To investigate the polyp-mineral interface the soft tissue of the polyp consisting of the calicoblastic ectoderm, mesoglea and epidermis, is removed by immersion in fresh water, followed by mechanical brushing and drying. Besides adult specimen skeletal material of coral larvae is also investigated. For this purpose new coral recruits were cultivated in filtered seawater at 390 ppm and 750 ppm atmospheric CO2 at 29°C at the aquaculture facilities, James Cook University, Australia. Corallite cross-sections of approx. 1 x 3 mm in size were cut from the cores perpendicular to the growth direction using a diamond cut-off wheel for TEM analysis (adult specimen only). The cross sections or complete larvae where then immersed in Gatan G1 epoxy resin and allowed to cure at 140°C on a hot-plate for 30 minutes to fill up the coral pores increasing the stability of the samples. The samples were manually polished down to approximately 50 µm thickness using diamond lapping pads (30 - 0.1 µm) and a tripod holder. Ultimately a bevel is applied, resulting in a sample edge thickness of approximately 20 µm. A molybdenum TEM slot is attached to the sample to provide structural support.
Focused ion beam milling
FIB lamellae are created on the thin polished sample edge using a FEI nova 200 Dual Beam FIB/SEM from the Leeds Electron Microscopy and Spectroscopy centre. The lamellae are created by applying the h-bar method: a platinum layer is deposited at the edge of the coral sidewall, perpendicular to the general alignment direction of the acicular crystals related to the targeted COC. A approximately 15 x 30 µm lamella is then excavated with a 30 kV Ga+ beam. Bulk milling is performed at 20 nA after which cleaning cross sections are applied at 5 nA and 0.30 nA. The final polish is performed with a 10 kV beam at an angle of 3º at 50 pA. The lamella is milled down to a 100 nm thin section and no lift out is performed to retain specimen context as well as structural support (Figure 2).
Scanning Electron Microscopy (SEM)
Instrumentation
In this study a FEI Sirion S-FEG FESEM (field emission SEM) was used from the York Jeol Nanocentre. This instrument is coupled with a Noran EDX system which uses an Oxford INCA analysis system and a 30 mm 2 light element Silicon-Lithium (SiLi) detector.
Sample preparation
Specimen preparation for SEM is usually much quicker and less involved as compared to TEM specimen preparation as the samples need not be electron transparent. Since there is a limit to the depth of field and we are interested in the cross section perpendicular to the growth direction of coral skeletons, a bulk cut followed by polishing is performed to a thickness of approximately 100-200 µm using the tripod polishing method, but without applying a bevel. This particular thickness range makes the specimen light transparent, which enables us to combine transmission optical microscope data with surface SEM data.
Specimens are subsequently lightly etched with deionised water (coral larvae) and dilute acetic acid-water mixture (adult coral specimen) to reveal the microstructure (Figure 3).
Summary of Conclusions (as published in recent paper*)
In this study we show that new insights can be gained on the nano- and microstructure of corallites by TEM investigation of large-scale (15 x 30 µm) FIB lamellae from adult and juvenile scleractinian coral skeletal specimens. By leaving the FIB prepared lamella within the coral skeletal context (no lift out) the lamella is mechanically more stable and durable while being directly comparable to the larger scale (several tens of microns) not ion-milled skeletal areas by optical analysis. Thus we could identify a crystallographic evolution from a centre of calcification outward over acicular and granular (daily) bands. In the adult Porites lobata specimen, a succession of randomly orientated nanocrystals with high porosity, followed by partly aligned nanocrystals with high porosity, to dense acicular crystals of several microns in length, was observed. A new layer of nanocrystals followed by the same succession is then repeated, in correlation with the contrast banding seen in transmission light images. Both the partly-aligned nanocrystals and the densely packed acicular bundles are preferentially oriented in the [001] crystallographic growth direction (Pmcn space group notation), (Figure 4).
We draw a parallel to the diurnal photosynthetic cycle of the zooxanthellae in symbiotic corals that control the levels of oxygen and carbon availabilities, both recognised as significant drivers of coral calcification processes. The transport of large amounts of glycerol by zooxanthellae and its potential impact on coral calcification was also discussed. This process could play a role in the specific alignment of the aragonite crystals as was demonstrated by synthetic experiments with OH-group containing additives by Sand et al. (2011) and the TEM investigation of these precipitates by the authors. The juvenile Acropora millepora specimen also showed the large acicular crystals interrupted by thin porous bands, but lacked the nanocrystalline phase, which may be linked to the absence of zooxanthellae and thus the typical daily cycle. But at this stage a comparison is not possible as we are dealing with different species and growth rates and morphologies are also likely to play an important role (Figure 5).
Finally, we conclude that our data do not support a growth mechanism via self-assembly of submicron-sized units associated with a mesocrystalline morphology, as the nanocrystalline areas are found to be polycrystalline on the micrometer scale with no extended co-orientation. We therefore conclude that the coral mineralisation follows a classical crystallisation pathway.


References
[1] D. B. Williams, C. B. Carter, Transmission electron microscopy: a textbook for materials science, Springer, 2009.
[2] S. Horiuchi, T. Hanada, M. Ebisawa, et al., ACS nano 3 (2009), pp. 1297-1304.
*Paper: Microstructural evolution and nanoscale crystallography in scleractinian coral spherulites Renée van de Locht et al, Journal of Structural Biology 183 (2013) pp.57-65

Free to read

This article has been unlocked and is ready to read.

Download


Digital Edition

IET 34.2 March 2024

March 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ecomondo Mexico

Apr 17 2024 Guadalajara, Nexico

IE Expo China 2024

Apr 18 2024 Shanghai, China

Hannover Messe

Apr 22 2024 Hannover, Germany

FORUMESURE

Apr 22 2024 Marrakech, Morroco

Asia Water 2024

Apr 23 2024 Kuala Lumpur, Malaysia

View all events