loader image

Ultrameter™ II 6PFCᴱ & 4P

Ultrameter™ II 6PFCᴱ & 4P

Product Info

We are proud of the trust our handheld water quality instruments and monitor/controllers have earned in the past. Our product line has evolved to a new level of outstanding performance and value in analytical instruments: the Ultrameter II series. While priced like affordable single-parameter instruments, the Ultrameter II does the job of up to seven instruments.

Accuracy You Can Trust

Both Ultrameter II models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor-based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Factory calibrated with NIST traceable solutions, each Ultrameter II may be supplied with both certification of traceability and NIST traceable solutions for definitive calibration.

Innovative Engineering

The Ultrameter II is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, merely:

  • Fill the cell cup
  • Push a parameter key
  • Take the reading

Temperature compensation and range selection are both rapid and automatic. The Ultrameter II is a true one-hand operation instrument.

Easy to Calibrate

All calibrations are quickly accomplished by pressing the ▲ or ▼ keys to agree with our NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory-set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life.

NEW! FCE TM FAC Readings

The Myron L® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L® Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry.

High Performance at a Low Cost

Beyond their affordable purchase price, Ultra-Fast, Ultra-Easy, Ultra- Powerful Ultrameter IIs save both time and money. Measure for measure, Ultrameter IIs give you a better return on your investment than any other handheld instrument. To see for yourself, contact your distributor or the Myron L® Company today.

ULTRAMETER™ II Features & Benefits:

  • 3 solution standards for greatest accuracy in diverse applications.
  • Fully automatic temperature compensation.
  • User adjustable temperature compensation (up to 9.99%/°C) which also allows TC to be disabled for applications requiring non-compensated readings.
  • User adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor.
  • Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests.
  • Non-volatile microprocessor provides data back-up, even when the battery is changed. This assures all calibrations and memory data will be retained.
  • Extended life pH/ORP sensor is user replaceable in the field.
Specifications

Ultrameter™ II 6PFCᴱ & 4P Specifications:

ULTRAMETER™ II
Display: 4 Digit Liquid Crystal Display
Dimensions: L x W x H 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 inches
Weight: 352 g/12.4 oz.
Case/conductivity cell material: VALOX*
Cell capacities pH/ORP: 1,2 ml/0.04 oz. Cond/TDS/Res: 5 ml/0.2 oz.
Power: 9V alkaline battery
Battery life: >100 hours (5000 readings)
Operating/storage temperature: 0 – 55°C/32 – 132°F
Protection ratings: IP67/nema 6
Waterproof to: 1 meter/3 feet
*™Sabic Innovative Plastics

Functional Specifications:

Conductivity Ranges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges
Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS)
Accuracy: ±1% of reading
Auto Temperature Compensation: 0–71°C / 32–160°F
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
TDS Ranges: 0–9999 ppm; 10–200 ppt; in 5 autoranges
Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
Accuracy: ±1% of reading
Auto Temperature Compensation: 0–71°C / 32–160°F
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
Resistivity Ranges: 10 KΩ–30 MΩ
Resolution: 0.01(<100 KΩ); 0.1(1 MΩ)
Accuracy: ±1% of reading
Auto Temperature Compensation: 0–71°C / 32–160°F
Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
pH Ranges: 0–14 pH
Resolution: 0.01 pH
Accuracy: ±0.01 pH**
Auto Temperature Compensation: 0–71°C / 32–160°F
ORP Ranges: ±999 mV
Resolution: 1 mV
Accuracy: ±1 mV
Free Chlorine FCE™ Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9
Resolution: 0.01 ppm
Accuracy: <1.00ppm ±0.3ppm** and ≥1.00ppm ±0.2ppm
Auto Temperature Compensation: 0–71°C / 32–160°F
Temperature Ranges: 0–71°C / 32–160°F
Resolution: 0.1°C/F
Accuracy: ±0.1°C
*442 Natural Water Standard™ Myron L® Company
**± .2 pH in presence of RF fields ≥ 3V/m and >300MHz
Applications

ULTRAMETER™ II Applications:

  • Irrigation Water
  • Hydroponics
  • Laboratories
  • Homeland Security
  • Reverse Osmosis
  • Deionization
  • Wastewater
  • Cooling Towers
  • Environmental
  • Desalination
  • Fountain Solutions
Accessories

Ultrameter™ II 6PFCᴱ & 4P Accessories:

  • bluDock™ Accessory Package includes bluDock, Macintosh/PC application software (Guardian2 TM) for downloading data and printed instructions.
    model: BLUDOCK
  • Certificates confirming the NIST traceability of an Ultrameter II are available (must be specified when placing instrument order).
    model: MC
  • Conductivity Standard Solutions are necessary to maintain accuracy and for periodic calibration of conductivity/TDS parameters. All Standard Solutions are NIST traceable for your complete confidence. Recommended values: KCl- 7000 (7 mS), 442-3000 (TDS), or NaCl-14.0 (mS) available in 2 oz/59 mL, 1 qt/1 L, and 1 gal/3,8 L.
  • pH Buffers are necessary to maintain accuracy and for periodic calibration of pH and ORP parameters. Calibration with pH 7 Buffer is especially important. All pH 4, 7, and 10 Buffers are NIST traceable and are available in 2 oz/59 mL, 1 qt/1 L, and 1 gal/3,8 L.
  • pH/ORP Sensor Storage Solution is available in 2 oz/59 mL, 1 qt/1 L, and 1 gal/3,8 L.
    model: SS20Z, SSQ and SSG
  • Certificate of NIST traceability for pH Buffer or Conductivity Standard Solutions are available (must be specified when placing solution order).
    model: SC
  • Hard protective case (small)
    model: UPP
  • Hard protective case (kit) with three buffers (pH 4, 7, and 10), one pH/ORP storage solution, and two standard solutions, (KCI-7000 and 442-3000). All bottles are 2 oz/59 mL.
    model: PKUU
  • Soft protective case is constructed of padded Nylon and features a belt clip for hands-free mobility.
    model: UCC (Blue)
    UCCDT (Desert Tan)
  • Replacement pH/ORP sensor is user-replaceable and features a unique/porous liquid-junction.
    model: RPR
  • ORP Sensor Conditioner Solution for precision ORP readings.
    model: ORPCOND
Downloads

Ultrameter™ II 6PFCᴱ & 4P Downloads:

Contact our sales department to purchase this item

Send Us A Message

Send us a message directly through our website.